Drenagem e enchimento a vácuo do sistema de arrefecimento
Cooling System Draining and Vacuum Filling

Texto da página
Link desta página: https://ranger.mbrace.com.br/oficina/729
Imagem: https://ranger.mbrace.com.br/img/oficina/729.webp
Engine Cooling
303-03C-8
303-03C-8
GENERAL PROCEDURES
Evacuating and Filling
1.
If the cooling system was completely drained,
fill the fluid container with the full cooling
system fill capacity plus 0.5L of additional
coolant.
If the cooling system was partially drained,
fill the fluid container with the removed and
spilled amount of coolant plus 1.0L of
additional coolant. When in doubt always use
the full cooling system fill capacity plus 0.5L
of additional coolant.
2. Remove the coolant expansion tank cap.
E139584
3.
1.
Close the valve, install the coolant hose and
place it into the fluid container.
General Equipment: Cooling System Vacuum
Tester and Refiller
2. Close the valve and connect the compressed
air hose.
1
2
E139671
4.
1.
General Equipment: Cooling System Vacuum
Tester and Refiller
2. Open the valve until the specificied vacuum
is achieved.
-0 .. 8 5 b a r
2
-0. 9 5 b a r
1
6-10bar
E139672
5.
Open the valve until the coolant reservoir
fluid level is at the MAX mark.
General Equipment: Cooling System Vacuum
Tester and Refiller
If no coolant is visible in the coolant
expansion tank, add 2.0L of coolant to the
fluid container and repeat the evacuating and
filling procedure.
E139673
6. Install the coolant expansion tank cap.
E139675