Oficina · página 1169 de 1428 · 412-00-8

Página 1169 do Manual de Oficina: Detecção eletrônica de vazamentos
Explicar no Gemini Ampliar imagem Traduzir texto
Texto da página
412-00-8 Climate Control System - General Information 412-00-8 GENERAL PROCEDURES Electronic Leak Detection Leak detection 4. Refer to: Air Conditioning (A/C) System Health and Safety Precautions (100-00 General Information, Description and Operation). 5. WARNINGS: Before starting leak detection, make sure that the area where it is to be done is well ventilated. If the surrounding air is contaminated with refrigerant gas, the leak detector will indicate this gas all the time. Odors from cigarette smoke and other chemicals such as antifreeze, diesel fuel, disc brake cleaner, or other cleaning solvents can cause the same problem. Prevent air movement while performing leak detection. The refrigerant identification equipment must be used before attaching the manifold gauge set. Otherwise the manifold gauge set may become contaminated. Contaminated refrigerant must be disposed of as special waste. Follow the manufacturer's instructions when working with the service unit. NOTE: At 24°C with the engine switched off, both manifold gauges should show 4.1 to 5.5 bar. Attach the manifold gauge set to the service gauge port valves. 6. For the leak test, close the manual valves on the gauge set. 7. If little or no pressure is indicated, charge the system with approx. 300g of refrigerant. Refer to: Air Conditioning (A/C) System Recovery, Evacuation and Charging (412-00 Climate Control System - General Information, General Procedures). 8. WARNING: Make sure that the surface is clean and free of foreign material. NOTE: Make sure that the leak detector is calibrated and set in accordance with the operating instructions. Use the R-134a automatic calibration halogen leak detector to leak test the refrigerant system. Follow the instructions included with leak detector for handling and operation techniques. 9. CAUTION: Do not let the detector sensing tip contact any substance as this could cause a false reading and may damage the sensor. Position the sensor about 5mm from the point to be checked. Circle each fitting completely. 10.If a leak is detected, repeat the leak detection process after blowing away the chemical detected with compressed air. 11. If a leak is detected again, extract the refrigerant under suction. Refer to: Air Conditioning (A/C) System Recovery, Evacuation and Charging (412-00 Climate Control System - General Information, General Procedures).