Detecção eletrônica de vazamentos
Electronic Leak Detection

Texto da página
Link desta página: https://ranger.mbrace.com.br/oficina/1169
Imagem: https://ranger.mbrace.com.br/img/oficina/1169.webp
412-00-8
Climate Control System - General Information
412-00-8
GENERAL PROCEDURES
Electronic Leak Detection
Leak detection
4. Refer to: Air Conditioning (A/C) System Health
and Safety Precautions (100-00 General
Information, Description and Operation).
5. WARNINGS:
Before starting leak detection, make
sure that the area where it is to be done
is well ventilated. If the surrounding air
is contaminated with refrigerant gas, the
leak detector will indicate this gas all
the time. Odors from cigarette smoke
and other chemicals such as antifreeze,
diesel fuel, disc brake cleaner, or other
cleaning solvents can cause the same
problem. Prevent air movement while
performing leak detection.
The refrigerant identification equipment
must be used before attaching the
manifold gauge set. Otherwise the
manifold gauge set may become
contaminated. Contaminated refrigerant
must be disposed of as special waste.
Follow the manufacturer's instructions
when working with the service unit.
NOTE: At 24°C with the engine switched off,
both manifold gauges should show 4.1 to 5.5
bar.
Attach the manifold gauge set to the service
gauge port valves.
6. For the leak test, close the manual valves on
the gauge set.
7. If little or no pressure is indicated, charge the
system with approx. 300g of refrigerant.
Refer to: Air Conditioning (A/C) System
Recovery, Evacuation and Charging (412-00
Climate Control System - General Information,
General Procedures).
8.
WARNING: Make sure that the surface
is clean and free of foreign material.
NOTE: Make sure that the leak detector is
calibrated and set in accordance with the
operating instructions.
Use the R-134a automatic calibration halogen
leak detector to leak test the refrigerant system.
Follow the instructions included with leak
detector for handling and operation techniques.
9.
CAUTION: Do not let the detector
sensing tip contact any substance as
this could cause a false reading and
may damage the sensor.
Position the sensor about 5mm from the point
to be checked. Circle each fitting completely.
10.If a leak is detected, repeat the leak detection
process after blowing away the chemical
detected with compressed air.
11. If a leak is detected again, extract the refrigerant
under suction.
Refer to: Air Conditioning (A/C) System
Recovery, Evacuation and Charging (412-00
Climate Control System - General Information,
General Procedures).