Recuperação, vácuo e carga do sistema de ar-condicionado (A/C)

Air Conditioning (A/C) System Recovery, Evacuation and Charging

Oficina · página 1166 de 1428 · 412-00-5 · parte 2 de 2

Página 1166 do Manual de Oficina: Recuperação, vácuo e carga do sistema de ar-condicionado (A/C)
Explicar no Gemini Ampliar imagem Traduzir texto
Texto da página
412-00-5 Climate Control System - General Information 412-00-5 GENERAL PROCEDURES Fill up with refrigerant oil. Refer to: Specifications (412-00 Climate Control System - General Information, Specifications). Refer to: Refrigerant Oil Adding (412-00 Climate Control System - General Information, General Procedures). 7. Evacuate the air conditioning system in accordance with the service unit manufacturer instructions. 8. NOTE: The system is leak-tight if the pressure increase does not exceed 20 mbar. Perform the leak test, by closing the hand valves on the gauge set, switching off the service unit vacuum pump and observing the low pressure gauge. 9. NOTE: This step is only necessary if the pressure increase exceeds 20 mbar. Locate and rectify any leaks in the A/C refrigerant circuit using a leak tester. General Equipment: UV Leak Detector General Equipment: Electronic Leak Detector General Equipment: Automatic Calibration Halogen Leak Detector 10.Add refrigerant oil to the air conditioning system. Refer to: Specifications (412-00 Climate Control System - General Information, Specifications). Refer to: Refrigerant Oil $GGLQJ (412-00 Climate Control System - General Information, General Procedures). 11. Fill the air conditioning system with liquid through the high-pressure connection. Refer to: Specifications (412-00 Climate Control System - General Information, Specifications). 12. 1. Open the shut-off valve on the high-pressure side. 2. Switch the service unit to "Fill" mode and fill the system with the specified quantity of liquid refrigerant (R134a). 13.Fill the air conditioning system with gas through the low-pressure connection. Refer to: Specifications (412-00 Climate Control System - General Information, Specifications). 14. 1. Open the shut-off valve on the low-pressure side. 2. Switch the service unit to "Fill" mode and fill the system with the specified quantity of gaseous refrigerant. 3. Add the remaining amount of refrigerant with the air conditioning switched on. To do so run the engine at about 1200-1500 rev/min. Set the air conditioning system to full cooling power and fresh air mode. Set the blower motor to the highest setting. Fill with the remainder of the specified fill capacity. 15.Disconnect the service unit. 16. 1. Close the shut-off valve. 2. Switch off the service unit. 3. Disconnect the service unit lines from the filling connections of the air conditioning system. 4. Screw the protective caps onto the charging connections. 17.Install all components in reverse order.