Alternador – 2.5L Duratec-HE (122kW/165PS) - MI4
Generator – 2.5L Duratec-HE (122kW/165PS) - MI4

Texto da página
Link desta página: https://ranger.mbrace.com.br/oficina/1248
Imagem: https://ranger.mbrace.com.br/img/oficina/1248.webp
414-02-2
Generator and Regulator
414-02-2
REMOVAL AND INSTALLATION
Generator – 2.5L Duratec-HE (122kW/165PS) - MI4(31 414 0)
Removal
NOTE: Removal steps in this procedure may
contain installation details.
1.
WARNING: When the battery cables are
connected, touching the vehicle body
with generator terminal B will generate
sparks. This can cause personal injury,
fire, and damage to the electrical
components. Always disconnect the
battery negative cable before performing
the following operation.
CAUTION: Do not allow any metal object
to come in contact with the generator
housing and internal diode cooling fins.
A short circuit may result and burn out
the diodes.
Refer to: Battery Disconnect and Connect
(414-01 Battery, Mounting and Cables,
General Procedures).
2. Refer to: Accessory Drive Belt (303-05
Accessory Drive - 2.5L Duratec-HE
(122kW/165PS) - MI4, Removal and
Installation).
3.
CAUTION: Take extra care not to
damage the wiring harnesses.
2. Torque: 15 Nm
3. Torque: 48 Nm
x3
3
1
2
E131274
Installation
1. To install, reverse the removal procedure.